Product Overview AIR CHICAGO ELITE is the newest generation of Chicago’s exclusive Air Induced Response French folder series. It brings increased speed and production enhancements to its proven dependable and precise air pulse folding system—no mechanical switches, metal slides, or punch blades. From towels and blankets to hospital gowns and pillowcases, Air Chicago Elite meets the folding needs of any laundry processing a wide variety of items of all sizes and types. Operators simply select the type of item being processed and everything else is done automatically. Redesigned primary folding deck uses newly enhanced ski width positioning for near-instant width adjustment. Streamlined crossfold section performs one or two crossfolds using positive air pulses through a precision inverter-controlled reversing conveyor for accuracy and repeatability.
Air Chicago Towel Folder Manual
Stacks are then transferred to the delivery conveyor on the innovative retractable “gentle-touch” transition discharge conveyor—designed for smoother operation and more accurate stacks during transition. Industries.
I assume the folder is faulting as it does not see the linen at the photocell at the end of the drop doors. Two possible issues - belts are loose or worn, the drop doors need to be cleaned and waxed. A third possible problem is damp towel. I have been cleaning the stainless steel and arms on towel folders for years. I presumably like pledge as it does not leave a buildup and is easy to get. Every shift I spray one side of my widest towel.
Feed it in wet side up then wet side down. Cleans and waxes the travel of the towel. On my PM I clean and wax all the stainless and guides. If you are already doing this then check the photo cell and belts. Mr Laundry Master Posts: 548 Joined: Fri Jul 10, 2009 4:54 am Location: Orlando, Florida.
If all your belts are tracking correct and everything is operational, then Sounds like you just need an adjustment. If you're not familier with the adjustments, then here goes. Push enter and CI (center) at same time.
Cursor over to 'stack'. Cursor will be flashing under 'stack'. Cursor over one spot to next number. That is the travel adjustment. Move that up or down until you drop where you need.
Push enter again and then center CI button to set. Site Admin Posts: 1127 Joined: Sun May 03, 2009 7:19 am Location: Northern KY.